LIFE Airports
Aria-aria a bassa quota
Adaptation and environment
Energy Efficiency
Active Inverter Recovery
Innovative Full Inverter Active Recovery System for energy recovery by means of an additional cooling circuit with inverter compressor.
This circuit allows an increase of the nominal power of the equipment, which increases its compactness.
Moreover, since this additional circuit exchanges heat between the fresh air and the extract air, under favorable temperature and humidity conditions, a high cooling performance is obtained.
This increases the nominal efficiency of the unit and the seasonal efficiencies under partial loads.
Furthermore, due to the INVERTER technology, they ensure the correct operation for the minimum flow rates established by the RITE update in 2021, going from an air flow rate of 1800m³/h to 1000m³/h.
Dynamic Recovery
It consists of an energy recovery system by means of an additional exchange coil (subcooler), placed in series with the unit’s air condenser, thus
the air condenser of the equipment, achieving a significant improvement in the efficiency of the equipment by reducing the electrical consumption of the equipment.
This system is advantageous compared to static recovery systems, because it avoids static recovery systems, because it avoids a higher consumption of the supply and return fans, due to the high pressure drop of these of these plate or rotary recuperators.
It can also be installed in units with exhaust fans.
extraction fans.
Integration systems with photovoltaic installations
Dimensiones Equipo estándar (mm) | |||||||
---|---|---|---|---|---|---|---|
Serie 0 | Serie 1 | Serie 2 | Serie 3 | Serie 4 | Serie 5 | Serie 6 | |
L | 2575 | 2575 | 3600 | 3900 | 4950 | 5300 | 5910 |
A | 1660 | 2260 | 2260 | 2260 | 2260 | 2260 | 2260 |
H | 1730 | 1730 | 2060 | 2060 | 2060 | 2485 | 2485 |
PERSEA EVO include Climanager electronic microprocessor control, pGD1 terminal controller and TH-Tune user terminal
Documentazione tecnica
KEYTER CATALOGUE
Ulteriori dettagli su questo prodotto
Il nuovo catalogo Keyter è uscito e disponibile gratuitamente.
Nell’edizione di quest’anno potrete scoprire la nostra gamma completa di prodotti e trovare ulteriori specifiche tecniche sulle unità Keyter.
Opzioni:
Sezione di filtraggio F
Free-cooling termico ed entalpico
Resistenza elettrica di supporto
Batteria ausiliaria per acqua calda con valvola a tre vie
Rilevatore di filtri sporchi
Rilevatore di fumi
Sonda di CO2 o VOC ambientale / condotto
Sonda di temperatura ambiente
Trattamenti anti-corrosione delle batterie (BLUECOAST, ALUCOAST,
GREYCOAST, BLYGOLD, COPPERFIN)
Altre tensioni elettriche
Scheda RS485 per comunicazione con protocollo MODBUS
Comunicazione BACNET / LONWORKS
Telecomando THT
Cambio a compressori scroll on-off in tandem (vedi dati tecnici)
Adattamento del gruppo per l’imbarco di ponti e container
Controlli
Le apparecchiature di produzione della serie SEILA comprendono il controllo elettronico programmabile CLIMANAGER
sviluppato specificamente per la gestione delle apparecchiature aria-aria e, in opzione, del terminale utente TH-Tune.
REFRIGERATORI E POMPE DI CALORE
CONTATTATECI
Come possiamo aiutarvi?
Siete alla ricerca di soluzioni HVAC+R (su misura) o avete domande?
Non esitate a contattarci.